Specifications

 

Main
range of productEasy Altivar 610
product or component typeVariable speed drive
product specific applicationFan, pump, compressor, conveyor
device short nameATV610
variantStandard version
product destinationAsynchronous motors
mounting modeCabinet mount
EMC filterIntegrated conforming to EN/IEC 61800-3 category C3 with 50 m
IP degree of protectionIP20
type of coolingForced convection
supply frequency50...60 Hz +/-5 %
network number of phases3 phases
[Us] rated supply voltage380...460 V - 15...10 %
motor power kW55 kW for normal duty
45 kW for heavy duty
motor power hp75 hp for normal duty
60 hp for heavy duty
line current111.5 A at 380 V (normal duty)
99.7 A at 460 V (normal duty)
95.9 A at 380 V (heavy duty)
84.0 A at 460 V (heavy duty)
prospective line Isc22 kA
apparent power79.5 kVA at 460 V (normal duty)
66.9 kVA at 460 V (heavy duty)
continuous output current88 A at 2.5 kHz for heavy duty
120 A at 2.5 kHz for normal duty
maximum transient current132 A during 60 s (heavy duty)
132 A during 60 s (normal duty)
asynchronous motor control profileOptimized torque mode
Constant torque standard
Variable torque standard
Output frequency0.0001…0.5 kHz
nominal switching frequency2.5 kHz
switching frequency1...8 kHz adjustable
number of preset speeds16 preset speeds
communication port protocolModbus serial
option cardSlot A: communication card, Profibus DP V1
Slot A: digital or analog I/O extension card
Slot A: relay output card
Complementary
output voltage<= power supply voltage
motor slip compensationAutomatic whatever the load
Adjustable
Not available in permanent magnet motor law
Can be suppressed
acceleration and deceleration rampsS, U or customized
Linear adjustable separately from 0.01 to 9000 s
braking to standstillBy DC injection
protection typeThermal protection: motor
Motor phase break: motor
Thermal protection: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive
frequency resolutionDisplay unit: 0.1 Hz
Analog input: 0.012/50 Hz
electrical connectionControl, screw terminal: 0.5...1.5 mm²
Line side, screw terminal: 70...120 mm²
Motor, screw terminal: 70...120 mm²
connector type1 RJ45 (on the remote graphic terminal) for Modbus serial
physical interface2-wire RS 485 for Modbus serial
transmission frameRTU for Modbus serial
transmission rate4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
type of polarizationNo impedance for Modbus serial
number of addresses1…247 for Modbus serial
method of accessSlave
supplyExternal supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
local signalling2 LEDs for local diagnostic
1 LED (yellow) for embedded communication status
2 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
width290 mm
height762 mm
922 mm with EMC plate
depth323 mm
net weight53.7 kg
analogue input number3
analogue input typeAI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits
AI2, AI3 software-configurable temperature probe or water level sensor
discrete input number6
discrete input typeDI1...DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm
DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
input compatibilityDI1...DI6: logic input level 1 PLC conforming to EN/IEC 61131-2
DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
discrete input logicPositive logic (source): DI1...DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)
Negative logic (sink): DI1...DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)
Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
analogue output number2
analogue output typeSoftware-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits
Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits
sampling duration5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input
2 ms +/- 0.5 ms (DI1...DI6)configurable - discrete input
5 ms +/- 1 ms (DI5, DI6)configurable - pulse input
10 ms +/- 1 ms (AQ1, AQ2) - analog output
accuracy+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
linearity errorAI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
AQ1, AQ2: +/- 0.2 % for analog output
relay output number3
relay output typeConfigurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
refresh timeRelay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
minimum switching currentRelay output R1, R2, R3: 5 mA at 24 V DC
maximum switching currentRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
isolationBetween power and control terminals
insulation resistance> 1 MOhm 500 V DC for 1 minute to earth
Environment
noise level78 dB conforming to 86/188/EEC
power dissipation in W969 W(forced convection) at 380 V, switching frequency 2.5 kHz
131 W(natural convection) at 380 V, switching frequency 2.5 kHz
volume of cooling air295 m3/h
operating positionVertical +/- 10 degree
electromagnetic compatibilityElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree2 conforming to EN/IEC 61800-5-1
vibration resistance1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance15 gn for 11 ms conforming to IEC 60068-2-27
relative humidity5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation-15…45 °C (without derating)
45…60 °C (with derating factor)
ambient air temperature for storage-40…70 °C
operating altitude<= 1000 m without derating
1000...4800 m with current derating 1 % per 100 m
environmental characteristicChemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standardsEN/IEC 61800-3
Environment 2 category C3 EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 60721-3
markingCE
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Weight70.5 kg
Package 1 Height47 cm
Package 1 width59 cm
Package 1 Length87 cm

 

 

Yorum Yap